SERVICE - FIT-TESTING HONEYWELL respirators in accordance to SS 548:2022 Code of practice for the selection, use and maintenance of respiratory protective devices

  • Product Code: fit test Honeywell Respirators
  • Availability: In Stock


Fit Testing in accordance to SS 548:2022 Code of practice for the selection, use and maintenance of respiratory protective devices  

(Previous Standard: SS 548: 2009. Code of practice for selection, use and maintenance of respiratory protective devices)


For FIT-TEST booking contact:  

T: (+65) 6266-0788 | E: service2@noah.com.sg | W: www.noah.com.sg

 

NOAH fit test trainers certified by:

3M

HONEYWELL

NORTH by HONEYWELL


SKU
550030L
550030M
550030S
HM501TL
HM501TM
HM501TS
HM502TL
HM502TM
HM502TS
770030L
770030M
770030S
RU85001L
RU85001M
RU85001S
54001
54001S
54001W
54001SW
760008A
760008AS
760008AW
760008ASW
RU65001L
RU65001M
RU65001S
N75001L
N75002L
N75003L
N75004L
N750052L
75SCL
7581P100L
7582P100L
7583P100L
7584P100L
75852P100L
75SCP100L
75FFP100
75FFP100NL
7580P100
7506N95
7506N99
7506R95
N750037
N750036
N750035
N750029


HW #54001 SZ: M/L RESPIRATOR; FULL FACEPIECE ELASTOMER (1EA/CASE)
HW #550030M SZ: M RESPIRATOR; HALF MASK ELASTOMER (12EA/CASE)
HW #550030L SZ: L RESPIRATOR; HALF MASK ELASTOMER (12EA/CASE)
HW #75SCL CARTRIDGE; MULTI-CONTAMINANT (1PR*18PKT/CASE)
HW #75SCP100L MULTI-CONTAMINANT & P100 CARTRIDGE (2EA*12PKT/CASE)
HW #N75001L CARTRIDGE; ORGANIC VAPOR (1PR*18PKT/CASE)
HW #N75002L CARTRIDGE; ACID GAS (1PR*18PKT/CASE)
HW #N75003L CARTRIDGE; ORGANIC VAPOR/ ACID GAS (1PR*18PKT/CASE)
HW #N750036 FILTER COVER (1PR*10PKT/CASE)
HW #N750037 FILTER COVER & HOLDER KIT (1PR*10PKT/CASE)
HW #N75004L CARTRIDGE; AMMONIA/ METHYLAMINE (1PR*18PKT/CASE)
HW #7506N95 FILTER; PARTICULATE N95 (10EA*12PKT/CASE)
HW #75FFP100 FILTER; P100 PANCAKE PARTICULATE (1PR*50PKT/CASE)
HW #75FFP100NL FILTER; P100 NUIS OV AG (1PR*50PKT/CASE)
HW #7580P100 CARTRIDGE; P100 PARTICULATE (1PR*72PKT/CASE)
HW #760008A SZ: M/L RESPIRATOR; FULL FACE MEDICAL GRADE SILICONE (1EA/CASE)
HW #770030S SZ: S RESPIRATOR; HALF MASK MEDICAL GRADE SILICONE (12EA/CASE)
HW #770030M SZ: M RESPIRATOR; HALF MASK MEDICAL GRADE SILICONE (12EA/CASE)


SPERIAN

FENZY

FERNEZ

Survivair 


Tight-fitting respirators must seal to the wearer’s face in order to provide expected protection. This includes disposable respirators (also called “filtering facepieces”). In Singapore, workers who need to wear respirators at work are required to undergo a medical assessment for fitness to use respirators. Workers with certain medical conditions such as lung problems may not be medically fit to use respirators. Please refer to the Singapore Standard SS 548:2009: Code of Practice for Selection, use and maintenance of respiratory protective devices for additional details.

In addition, fit tests should be performed:

  • Whenever a different size, style, model or make of respirator is used.
  • When any facial changes occur that could affect fit, such as significant weight fluctuation or dental work.

Qualitative Fit Test (QLFT)

A qualitative fit test (QLFT) may only be used to fit-test:

  • Negative-pressure, air-purifying respirators, as long as they’ll only be used in atmospheres where the hazard is at less than 10 times the permissible exposure limit (PEL).
  • Tight-fitting facepieces used with powered and atmosphere-supplying respirators.

Each QLFT method uses seven exercises performed for 1 minute each:

  • Normal breathing.
  • Deep breathing.
  • Moving head side to side.
  • Moving head up and down.
  • Bending over (or jogging in place if the fit test unit doesn’t permit bending at the waist).
  • Talking.
  • Normal breathing again.


Full and Half face Respirator Fit Test

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha