MULLION FIRE FIGHTER, COMPLETE, C/W: SOLAS / EN469 SIZE: L
- Product Code: FIREMAN SUIT-L
- Item Code: PICK-MUL-FSUIT-02
- Availability: In Stock
MULLION FIRE FIGHTER, COMPLETE, C/W: SOLAS / EN469 SIZE: L
(Part of fireman's outfit solas requirements)
FIRE FIGHTING SUIT, MULLION, FIRE FIGHTER
INTERVENTION JACKET & TROUSERS WITH SUSPENDERS,
531(1MMF & 1MPF), COLOUR: ORANGE, TWO‐LAYER
ARAMID (NOMEX) THERMAL INSULATION BARRIER, C/W:
CARRYING BAG
DOUBLE CERTIFICATION: EN469 AND SOLAS
MADE IN BELGIUM
Features:
- Professional fire fighter complete suit that complies to SOLAS/MED regulations
Specifications:
- Fireman Intervention Jacket & Trousers, 531(1MI9)
- Fireman Helmet, H1000 (2MZP)
- Fireman 5-Finger Gloves, (2MZO)
- Fireman Boots, 9687L (2MZN)
- Fireman Carrying Bag, (139Z)
Applications:
- Offshore Facilities
- Supply / Commercial Vessels
- Bulk Carriers
- Oil And LPG Tankers
- Container And Load Vessels That Operate In Cold Water
Certifications / Safety Approvals:
- SOLAS
- EN 469 : 2005 + A1 : 2006 / Xf2 Xr2 Y1 Z2
- EN ISO 13688 : 2013
- EN 443
- EN 659
- EN ISO 20345/EN15090
EN 469:2005
Performance requirements for protective clothing for firemen
The EN 469:2005 standard offers performance requirements for protective clothing for firemen. It demands high performances, which are verified in 20 tests. Essentially, the standard determines 4 key values: Xf (flame), Xr (radiation), Y (waterproofness) and Z (breathability).

Flame (Xf)
The EN ISO 9151 test method (flame test) involves heat transmission (flame) with a heat flux of 80 kW/m2.
Xf2 Xf1 HTI Heat Transfer Index Level 2 Level 1 HTI24 ≥ 13s ≥ 9s HTI24 - HTI12 ≥ 4s ≥ 3s Level 1 is the lowest level; level 2 is the highest level.Radiant heat (Xr1 or Xr2)
The transmission of heat (radiation) is tested in the EN 6942 test method. There is a heat flux of 40kW/m2.
Xr2 Xr1 RHTI Radiation HTI Level 2 Level 1 RHTI 24 ≥ 18s ≥ 10s RHTI 24 - RHTI 12 ≥ 4s ≥ 3s Just as for the previous test, level 1 is the lowest level, while level 2 is the highest one.MORE ABOUT THE TEST METHOD EN ISO 6942Water tightness (Y1 or Y2)
Waterproofness test EN 20811
- Y1 < 20 kPa
- Y2 ≥ 20 kPa
Y1: garments without membrane ; Y2: garments with membraneMORE ABOUT THE TEST METHOD EN 20811Breathability (Z1 or Z2)
MORE ABOUT THE TEST METHOD EN 31092Water vapour resistance EN 31092
Level Z1 > 30m² Pa/W.
Z1 indicates a higher water vapour resistance than Z2.
This garment is less breathable.Level Z2 ≤ 30 m² Pa/W
This garment has a lower water vapour resistance.
It is more breathable.
BUNKER SUIT/ BUNKER GEAR
bunker gear
bunker suits for firefighters
fire fighting bunker gear
EN469 standard Firemans outfit
FIREMAN OUTFIT SUITS COMPLETE SET (EUROPEAN NORM EN469 STANDARD)
EN469 IMPA Code 330911 Fireman’s Outfits
IMPA 330911 FIREMAN'S OUTFIT
330901-FIREMAN’S SUITS COMPLETE, H.K.APPROVED
330912 FIREMAN'S COAT UNLINED
FIREMAN'S SUIT COMPLETE SET, ARAMID FIBRES, NON- ALUMINIUM, SOLAS APPROVED, WITH CERTIFICATE
330921 |
FIREMAN'S OUTFIT COMPLETE (CLOTHES/BOOTS/GLOVES/HELMET) WITH MED/SOLAS CERTIFICATES |
330921 | FIREMAN'S SUITS COMPLETE N.M.D.APPROVED | 消防服 |