MULLION FIREMAN JACKET & TROUSERS, 531(1MI9) SIZE: XL

  • Product Code: 1MMF & 1MPF
  • Item Code: CLFF-MUL-FB...-XL
  • Availability: In Stock

MULLION FIREMAN JACKET & TROUSERS, 531(1MI9) SIZE: XL​ 

 

MULLION FIREMAN SUIT, COMPLETE

C/W: JACKET, TROUSERS, ORANGE (EN469),


PAB FIRE COMPACT FIREMAN HELMET, YELLOW/WHITE, GLOVES 2MZO RESCUE2 (EN659), BOOTS, ETCHE, FIREMAN SABF BOOTS (EN 15090:2012, EN ISO 20345 S5) & CARRYING BAG EC-MED APPROVED TO SOLAS, EN 469 2020  (Xf2, Xr2, Y2, Z2)


(Part of fireman's outfit solas requirements)

FIRE FIGHTING SUIT, MULLION, FIRE FIGHTER

INTERVENTION JACKET & TROUSERS WITH SUSPENDERS,

531(1MMF & 1MPF), COLOUR: ORANGE, TWO‐LAYER

ARAMID (NOMEX) THERMAL INSULATION BARRIER, C/W:

CARRYING BAG

DOUBLE CERTIFICATION: EN469 AND SOLAS

MADE IN BELGIUM

Features:

  • Professional fire fighter jacket and trousers that complies to SOLAS/MED regulations

Specifications:

Fire-Fighting Jacket

  • Fire resistant garment with two-layer aramid thermal insulation barrier. Breathable. Excellent wicking performance. Outer shell treated with water repellent finish.
  • Sleeve narrowing by touch and close fastening
  • Stand-up collar with touch and close fastening to protect the neck
  • Front zip closure under flap
  • Flame resistant triple trim reflective tape on chest, back and arms for optimum visibility day and night

Fire-Fighting Trousers

  • Fire resistant garment with two-layer aramid thermal insulation barrier. Breathable. Excellent wicking performance. Outer shell treated with water repellent finish.
  • Front fly with zipper
  • Adjustable elasticated shoulder braces
  • Flame resistant triple trim reflective tape on legs for optimum visibility day and night

Applications:

  • Offshore Facilities
  • Supply / Commercial Vessels
  • Bulk Carriers
  • Oil And LPG Tankers
  • Container And Load Vessels That Operate In Cold Water

Certifications / Safety Approvals:

  • SOLAS
  • EN 469 : 2005 + A1 : 2006 / Xf2 Xr2 Y1 Z2
  • EN ISO 13688 : 2013

What is fire suit EN 469 2020?

This document specifies minimum performance requirements for protective clothing designed to be worn during firefighting activities. The requirements detailed in this document cover design, heat and flame, mechanical, chemical, comfort, and visibility.


  • Flame (Xf)

    The EN ISO 9151 test method (flame test) involves heat transmission (flame) with a heat flux of 80 kW/m2.

    Xf2Xf1
    HTI Heat Transfer IndexLevel 2Level 1
    HTI24≥ 13s≥ 9s
    HTI24 - HTI12≥ 4s≥ 3s
    Level 1 is the lowest level; level 2 is the highest level.
  • Radiant heat (Xr1 or Xr2)

    The transmission of heat (radiation) is tested in the EN 6942 test method. There is a heat flux of 40kW/m2.

    Xr2Xr1
    RHTI Radiation HTILevel 2Level 1
    RHTI 24≥ 18s≥ 10s
    RHTI 24 - RHTI 12≥ 4s≥ 3s
    Just as for the previous test, level 1 is the lowest level, while level 2 is the highest one.
    MORE ABOUT THE TEST METHOD EN ISO 6942
  • Water tightness (Y1 or Y2)

    Waterproofness test EN 20811

    • Y1 < 20 kPa
    • Y2 ≥ 20 kPa
    Y1: garments without membrane ; Y2: garments with membrane
    MORE ABOUT THE TEST METHOD EN 20811
    Sioen - a water penetration test is performed
  • Breathability (Z1 or Z2)

    Water vapour resistance EN 31092

    Level Z1 > 30m² Pa/W.
    Z1 indicates a higher water vapour resistance than Z2.
    This garment is less breathable.

    Level Z2 ≤ 30 m² Pa/W
    This garment has a lower water vapour resistance.
    It is more breathable.

    MORE ABOUT THE TEST METHOD EN 31092


Firefighter's outfit (Close proximity clothing)  SOLAS Reg 10.10.1.1 Protective clothing for firefighters. Size 54-56 (L) Regular Type Description: Standard: EN 469-2005 | SOLAS Reg 10.10.1.1 Protective clothing for firefighters.  Type Description: Standard: EN 469-2005

EN469 compliant Fireman's outfits with certificate


Fireman's Outfit EN469:2020 (EN469 standard with XYZ on Level 2) SOLAS Approved

Tier 1 HRI Firefighting Suit

BUNKER SUIT/ BUNKER GEAR

bunker gear

fire fighting bunker gear


bunker suits for firefighters

IMPA 330903 - FIREMAN SAFETY COAT

330912 FIREMAN'S COAT UNLINED

Firemans coat unlined, UK, DOT/USCG Approved required as per SOLAS regulation 

Firemans trouser unlined, UK, DOT/USCG Approved required as per SOLAS regulation 

IMPA coding:330906

FIREMAN'S SUIT COMPLETE SET, ARAMID FIBRES, NON- ALUMINIUM, SOLAS APPROVED, WITH CERTIFICATE

Chinese name:消防员裤子

Write a review

Note: HTML is not translated!
    Bad           Good