SERVICE - TESTING LEVEL A SUIT
- Product Code: CLCH-LKL-YSVCE-
- Product SKU:
- Item Code: CLCH-LKL-YSVCE-
- Availability: In Stock
For service/testing booking
contact:
T: (+65) 6266-0788 | E: service2@noah.com.sg | W: www.noah.com.sg
Overview
Industry standards recommend that a visual inspection and pressure testing of Level A ensembles be done at the following times:
- Upon receipt from supplier
- At least once per year
- After the garment is worn and before the garment is worn again
Note: Contaminated, damaged or altered garments should not be re-used.
Note: All suits must be decontaminated before testing at our service department
Maintenance
and Repairs (Page 4 of manual)
Upon
receipt, the Level A suit should be tested to insure that
no damage has occured during shipment.
After that, the Level A suit should be tested after every use and at least annually,
whether it is used or not.
If the Level A suit fails the test, see “Testing” and “Returns” for more information. In addition to testing,
the Level A suit must be inspected after every use and at least annually. A Level A Inspection Checklist has been provided
at the back of this manual to assist in the inspection. When replacing exhaust valve diaphragms after testing or inspection,
care must be taken to insure that the diaphragm locking stem is secured properly into the positioning groove on the
stem. If the diaphragm locking stem is pulled too far into the valve housing (beyond the positioning groove) the diaphragm
may not seat properly. Visual inspection from both outside and inside the garment is recommended to assure proper seating
of the diaphragm. Check the zipper for overall condition, worn or damaged teeth, and ease of operation Lubricate zipper lightly with paraffin, which is readily available in most grocery stores. Paraffin should be applied lightly to the inner and outer elements. After cycling
the
zipper several times, the excess flakes should be removed.
Do
not use a sticky lubricant which could
Level A Test Kit for Lakeland Level A Suits
Style Number: 00010
Pressure test kit for Lakeland Level A suits.
Kit Features:
- Pressure testing for Lakeland Interceptor® level A suits per ASTM F1054 and EN464 (Pressure testing for Gas-Tight suits).
- Requires external air supply source.
- Exclusive for Lakeland Level A suits.
level a suit testing
INSPECT TYCHEM DUPONT CHEMICAL SUIT
C/W MAINTENANCE LABEL
SERIAL NO.; M130N2WN4, M130N2WN2