RIKEN KEIKI (RKI), GX-2009 Portable Multi Gas Detector Confined Space 4 Gas Monitor
- Product Code: GX-2009
- Availability: Pre-Order
RIKEN KEIKI (RKI), GX-2009 Portable Multi Gas Detector Confined Space 4 Gas Monitor
Features
- Simultaneous detection of 4 gases, LEL, O2, H2S & CO
- Smallest / Lightest 4 gas monitor on the market
- Dual audible alarm ports
- 3 visual alarm LED’s
- Vibration alarm
- IP-67 water-resistant/dustproof design
- Calibration and bump test lock out or reminder controls
- 20 hours of operation (NiMH batteries)
- Automatic backlighting at alarm
- Impact resistant over-mold body, RFI shielded body
- STEL and TWA readouts
- Intrinsically safe, CSA, C/US classified, IECEx / ATEX approved, SOLAS XI-1/7 Compliant, MSHA approved version available
Description
The smallest and lightest 4-gas portable multi gas detector in the world. Weighing only 4.6 ounces, it fits in the palm of your hand (2.75” H x 2.95” L x .98” D). The GX-2009 simultaneously monitors and displays combustibles, oxygen, carbon monoxide, and hydrogen sulfide. The GX-2009 represents the latest evolution of gas detection technology. Advancements include dual audible alarm ports and alarm LED’s on 3 sides of the instrument, so that alarm conditions are obvious from multiple perspectives especially in high noise environments. Other features include a water resistant and dust-proof design with IP 67 rating, an impact resistant rubber over-mold body that is RFI resistant, and a large capacity data logging system included as standard. Other standard features are vibration alarm, auto-calibration, calibration and bump test lock out or reminder control, STEL / TWA readings, peak hold, auto backlighting at alarm on a large LCD display, and it even tells the time! All of these controls and features are operated through 2 simple glove friendly buttons.
The NiMH battery set will operate for 20 hours and will fully charge in 3 hours. A huge capacity data logging function is a standard feature on all GX-2009 instruments. The data logging software will store up to 100 calibration records and is Windows XP, 7, 8, and 10. The GX-2009 is also functional with the SDM-2009 single calibration station and the Data Cal 2000 instrument maintenance system. The GX-2009 is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies. Each miniaturized sensor is manufactured with the same high quality control that has made RKI sensors and instruments the most reliable and long lasting monitoring devices in the industry
GX-2009 Mining Version
RKI is proud to offer the smallest and lightest 4-gas monitor with an MSHA approval. MSHA (Mine Safety and Health Administration) approval allows this version of the GX-2009 to be used in underground mines, tunnels and excavations under MSHA jurisdiction. The GX-2009 Mining Version simultaneously monitors and displays % volume combustibles, oxygen, carbon monoxide, and hydrogen sulfide.
Applications
- Portable multi gas detector
- Confined spaces
- Refineries/petrochemical
- Utilities
- Hazardous material
- Water/wastewater
- Fire services
- Construction
Portable Multi Gas Detector Configurations
- 4 gas, LEL / O2 / H2S / CO • 3 gas, LEL / O2 / H2S • 3 gas, LEL / O2 / CO
- 2 gas, LEL / O2 • 2 gas, O2 / H2S • 2 gas, O2 / CO
- Single gas LEL, O2, CO, H2S
Application
- Personal monitoring
- Confined spaces
- Refineries/petrochemical
- Utilities
- Hazardous material
- Water/wastewater
- Fire services
- Construction
Specifications
The GX-2009 is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies. Each miniaturized sensor is manufactured with the same high quality control that has made RKI sensors and instruments the most reliable and long lasting monitoring devices in the industry.
Gas Detected | Combustible Gases (Methane as standard) | Oxygen (O2) | Hydrogen Sulfide (H2S) | Carbon Monoxide (CO) |
---|---|---|---|---|
Detection Principle | Catalytic combustion | Galvanic cell | Electrochemical cell | |
Detection Range (Increments) | 0 ~ 100% LEL (1% LEL) | 0 ~ 40.0% Vol. (0.1% Vol.) | 0 ~ 100.0 ppm (0.5 ppm) | 0 ~ 500 ppm (1 ppm) |
Accuracy Statement | ± 5% of reading or ± 2% LEL (whichever is greater) | ± 0.5% O2 | ± 5% of reading or ± 2 ppm H2S (whichever is greater) | ± 5% of reading or ± 5 ppm CO (whichever is greater) |
Sampling Method | Diffusion sampling standard / hand aspirator or motorized pump optional | |||
Display | Digital LCD displays all four gases simultaneously, with auto backlight | |||
Preset Alarms (User Adjustable) Overscale alarm (Non-adjustable) | 1st alarm 10% LEL 2nd alarm 50% LEL Over alarm 100% LEL | Low alarm 19.5% High alarm 23.5% Over alarm 40.0% | 1st alarm 5 ppm 2nd alarm 30 ppm TWA alarm 1 ppm STEL alarm 5 ppm Over alarm 100 ppm | 1st alarm 25 ppm 2nd alarm 50 ppm TWA alarm 25 ppm STEL alarm 200 ppm Over alarm 500 ppm |
Types of Alarms | Gas Alarm: 2 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing. Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error | |||
Display of Alarm | Gas Alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), flashing gas value, vibration Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message | |||
Operating Temp. & Humidity | -4°F to 122°F (-20°C ~ +50°C), 0 to 95% RH, non-condensing (splash resistant) | |||
Response Time | Within 30 seconds (T90) | |||
Continuous Operation | 20 hours after a 3 hour full charge (14 hours after 90 min charge) | |||
Power Source | Direct charging NiMH batteries, set of 2 | |||
Safety Design / Approvals | IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available) c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D | |||
Dimension & Weight | 2.7” H x 3” W x 1” D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130 g) | |||
Case Material | High impact over molded rubber. Dust and water resistant with IP-67 approval. | |||
Controls | Two buttons: POWER / MODE, AIR | |||
Datalogging | Standard with all instruments. Stores 8 alarm trend sessions where readings are recorded 30 minutes before and after an alarm event. 3,600 data point capacity with a log time range of 10 to 300 hours (based on programmable interval times); and stores up to 100 calibration records. | |||
Required Accessories | Battery charger | |||
Standard Accessories | Alligator clip 13-0116RK NiMH batteries (set of 2) 49-1609RK Charging station with 115/220 VAC power supply (also available without power supply, 49-2170RK) 49-2170RK-01 Product CD (includes datalogging software) 71-8002RK | |||
Optional Accessories | Belt Clip 13-0117RK Padded carrying case for GX-2009 and accessories 20-0112RK-01 Charging station, 115/220 VAC powered for 2, 3, 4, or 5 instruments 49-2170RK-XX Charging station with 12 VDC power supply and vehicle adapter plug 49-2171RK 12 VDC adapter with vehicle plug (does not include charger base) 49-2020RK RP-2009 pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available) 81-1177RK RP-6 sample drawing pump with 10’ hose and probe (up to 40’ hose available) 81-1166RK Hand aspirated sample draw with 10’ hose and probe (up to 40’ hose available) 81-1160RK USB to IrDA downloading cable 47-5084RK-01 SDM-2009 single calibration station 81-SDM2009-01 | |||
Configurations |
| |||
Warranty | Two years material and workmanship |
# | Part Number | Description |
1 | 21-1880RK | Front case, GX-2009 |
2 | 07-6017RK-01 | Gasket for GX-2009 case, one each |
3 | 30-1054RK | Vibration motor for the GX-2009 |
4 | 51-1119RK | LCD module assembly with flat cable for GX-2009 |
5 | 57-2052RK | PCB main assembly, GX-2009 |
5 | 65-7001RK | Dummy sensor for GX-2001 or GX-2009 |
6 | 21-1881RK | Case, rear, GX-2009 |
7 | 10-1098RK-01 | Screw with split lock and flat washers for alligator or belt clip, GX-2009, 1 each |
8 | 10-1104RK | Screw for case or sensor retainer, M2 x 10 mm, GX-2001 or GX-2009, pack of 100 |
9 | 33-1113RK-01 | Metal mesh filter for buzzer hole, GX-2009, 1 each |
9 | 49-0115RK | 115 / 220 VAC Adapter for charger (charger base not included), GX-2009 |
10 | 07-6018RK | Gasket for buzzer hole, GX-2009 |
11 | 24-5000RK | Flexible printed circuit (FPC), GX-2009 |
12 | 49-1050RK | Battery, silver oxide, SR 616, 1.55 volts, GX-2009 |
13 | 49-1609RK | NiMH battery set with hardware for GX-2009, set of 2 batteries |
14 | 13-0119RK | Alligator clip, GX-2009 |
17 | 21-1883RK | Sensor case with PCB assembly, GX-2009 |
18 | 07-6008RK | O-ring gasket for sensor case, GX-2009, pack of 10 |
18 | 07-6008RK-01 | O-ring gasket for sensor case, GX-2009, 1 each |
19 | OS-BM2 | Sensor, Oxygen (O2) for GX-2001/GX-2003/GX-2009/GasWatch 2/OX-01 |
20 | NC-6264A | Sensor, LEL, for GX-2001/GX-2003/GX-2009/GP-01 |
21 | ES-1821 | Sensor, Carbon Monoxide (CO) for GX-2001/GX-2003/GX-2009/GasWatch 2/CO-01 |
22 | ES-1827i | Sensor, Hydrogen Sulfide (H2S) for GX-2009 |
23 | 07-6019RK | Sensor chamber gasket,for sensor retainer,GX-2009 |
24 | 21-1882RK | Sensor retainer, GX-2009 (inner piece) |
25 | 33-7114RK | Filter disk, H2S scrubber, 5 pack, for combustible diffusion port, set of 5 |
26 | 33-7102RK | Filter, charcoal, for CO sensor, pack of 5 |
26 | 33-7102RK-01 | Filter, charcoal, for CO sensor, 1 each |
27 | 07-6021RK | Gasket, sensor retainer |
28 | 33-0172RK | Sensor Cover, water proof, sheet for 4 sensors, GX-2009, 1 each |
29 | 21-1884RK | Sensor cover, GX-2009 (outside piece) |
30 | 10-1104RK-01 | Screw for case or sensor retainer, M2 x 10 mm, GX-2001 or GX-2009, 1 each |
31 | 13-0112RK | Wrist strap, GX-2001/GX-2003 |
32 | 13-0117RK | Belt clip, GX-2009 |
Gas detector for confined space
RENTAL OF GAS DETECTORS AVAILABLE - Click Here
Personal multigas detector
WSH, 27 November 2020:
Employers, principals and contractors performing similar work are advised to put in place the necessary controls to protect workers when working with inert gases (e.g. argon). The use of inert gases in a confined space (the adjoining pipe in this case) may inadvertently create an asphyxiation hazard. Communicate to workers the dangers of working with inert gases. Establish and implement a work procedure for the safe application of inert gas in preparation for welding works. Avoid the use of inert gas wherever possible. If inert gas must be used, equip workers with a portable gas detector to detect the lack of oxygen and/or presence of toxics/flammables depending on the work environment. Advise workers never to insert their head into a confined space so long as the atmosphere within is not certain.
personal and portable gas detector
Confined Space Gas Detector Meter
MULTI GAS DETECTOR POCKETABLE TYPE 33 05 27
330539 COMBINATION GAS DETECTOR, PORTABLE
*Compliance To IMO & MPA Circular MSC1./Circ. 1477 dtd 9 Jun 2014
1. The Maritime Safety Committee (MSC) of the International Maritime
Organisation (IMO) adopted SOLAS regulation III/19.3.6.2.3 relating to enclosed
space entry and rescue drills, by Resolution MSC.350(92). The Merchant Shipping
(Safety Convention) (Amendment No. 2) Regulations 2014 which gives effect to the
Resolution entered into force on 1 January 2015.
2. The MSC at its ninety-third session confirmed that regulation III/19.3.6.2.3
does not introduce carriage requirements for atmosphere testing instruments for
enclosed spaces.
3. The MSC at its ninety-fourth session, in adopting Resolution MSC.380(94)
recognised the need to implement the new SOLAS regulation XI-1/7 early in order to
expedite the carriage of portable atmosphere testing instruments. MSC/Circ.1485
invited SOLAS Contracting Governments to voluntarily implement SOLAS regulation
XI-1/7 to ships under their flags, as soon as practicable, taking into account that the
entry-into-force date of the corresponding amendment to SOLAS is 1 July 2016.
4. In view of the testing of atmosphere of enclosed spaces is critical for the safe
entry by ship crew and the carriage of portable atmosphere testing instrument
introduced by regulation XI-1/7 is essential to satisfying the requirement of regulation
III/19.3.6.2.3, the Director of Marine has decided to implement regulation XI-1/7
early. Singapore registered ships to which chapter I of the Merchant Shipping (Safety
Convention) Regulations apply, shall implement regulation XI-1/7 as soon as
possible but not later than 1 July 2015.
5. Shipowners should take into consideration MSC.1/Circ.1477 “Guidelines to
facilitate the selection of portable atmosphere testing instruments for enclosed
spaces as required by SOLAS regulation XI-1/7”, when selecting portable
atmosphere testing instrument for enclosed spaces as required by regulation XI-1/7.
1 |
MULTI GAS DETECTOR FOR CARGO
HOLDS |
330539 |
2 |
SAMPLING PIPE WITH 2OMTR
SAMPLING HOSE |
330592 |
3 |
FLOATING TYPE SAMPLING DEVICE 20
MTR |
330593 |
4 |
Gas Monitor Multi Toxic -
MONITOR MULTI TOXIC GAS, PERSONAL RIKEN GX-2009 |
330520 |
330520 |
MONITOR MULTI TOXIC GAS, PERSONAL RIKEN GX-2001 (model
GX-2009) |
Alternative to:
330582 | PERSONAL FLAMMABLE AND OXYGEN GAS DETECTOR, PAC EX II, DRAEGER | 个人用可燃瓦斯检测器,PAC,EX,II,DRAEGER |
Multi toxic gas monitor, GX 2009 33 05 20