Vetter Connectable Bags C.Tec 12 174 psi
- Product Code: C.Tec 12
- Availability: Pre-Order
Vetter Connectable Bags C.Tec 12 174 psi
(Part of National CERT Equipment supply | Part of IBC Code Requirements | Part of IGC Code Requirements)
Features:
- 3 different lifting-bag sizes
- 4 control devices (2 deadman versions, 2 fitting)
- Many different compressed air sources, e.g. compressed air bottle, compressor, compressed air connection to the vehicle
Specifications:
- Working pressure: 12 bar (174 psi)
- Test pressure: 18 bar (261 psi)
- Burst pressure, at least: 48 bar (696 psi)
Product |
Art. no. |
max. Lifting power with full areal contact* t |
Lifting power with full contact with load plate, max t |
End lifting capacity t |
Lifting height by end lifting capacity cm |
max. lifting height* cm |
air requirement at 12bar / 174 psi litres |
Diameter cm |
Weight, approx. kg |
Insertion height cm |
---|---|---|---|---|---|---|---|---|---|---|
VCB 30 C.Tec 12 | 1316003700 | 30.1 | 14 | 7 | 21 | 29.3 | 420 | 56.5 | 18 | 9 |
VCB 75 C.Tec 12 | 1316003800 | 74.7 | 41 | 12 | 35 | 45.9 | 1.476 | 89 | 34 | 9 |
VCB 172 C.Tec12 | 1316003900 | 171.8 | 108 | 15 | 59 | 69 | 5.048 | 135 | 58 | 11.5 |
cert equipment singapore
CERT TIER 1 2 3 and HRI - For more information, please contact us at T: (+65) 6266-0788 | E: nis3@noah.com.sg
NATIONAL CERT STANDARD
CLASSIFICATION OF CERT PREMISES | MINIMUM TRAINING | MINIMUM EQUIPPING | BASIC TASKING | |||||
PPE1 | MITIGATION | FIRST AID | COMMUNICATION | |||||
P&FM Premises | Tier 1 P&FM |
Premises storing more than 5 metric tons of Petroleum & Flammable Material |
WSQ Respond to Fire & Hazmat Emergency (3 days)
CERT First Aider Couse (1 day) | · Chemical suits2 · Rubber gloves2 · Rubber boots2 · Firefighting suit · Firefighting helmet · Goggles / Face shields · Firefighting gloves · Firefighting boots · Breathing apparatus |
· HazMat absorbents2 · Leak sealing devices2 · Overpack drums2 · Fire extinguishers (appropriate class) · Firefighting nozzles & hoses |
· First aid kit · Foldable stretcher · Blanket · AED |
· Loud hailer · Walkie-talkie1 | · Contain HazMat leaks2 · Prevent spread of HazMat2 & fires · Activate HazMat2 & fire protection systems · Contain and mitigate incipient stages of HazMat2 & fire incidents · Perform first aid, CPR & use AED · Implement In-Place Protection · Conduct mass evacuation · Assist emergency responders |
Fire Safety Manager Premises | Tier 1 HRI |
Public & Industrial premises with FSM and classified as High Risk Installations by SCDF |
& |