Fire Extinguishers


cert equipment singapore

CERT TIER 1 2  3 and HRI -

For more information, please contact us at T: (+65) 6266-0788 | E: nis_sales@noah.com.sg


CERT (Company Emergency Response Team)

The CERT Scheme was expanded to include a broader group of Public and Industrial premises with the amendments to the Fire Safety Act on 01 September 2013 and 01 March 2014.
 

In the updated Fire Safety Act (Chapter 109A), all premises with Fire Safety Managers are required to set up a CERT. In addition, all premises with a Fire Certificate are required to develop an Emergency Response Plan (ERP). Compared to the previous Fire Emergency Plan (FEP), the ERP is a more comprehensive response plan that includes the evacuation plan, the in-place protection plan, the arson prevention plan and the incident mitigation plan. More details on the ERP can be found on the Emergency Response Plan webpage.


 

In Accordance to NATIONAL CERT STANDARD : TIER 1 HRI

cert team requirements

For Tier 1 P&FM Premises only:

 Premises storing 5 or more metric tonnes of P&FM


Personal Protective Equipment (PPE)

a. Disposable chemical suit

b. Rubber gloves

c. Rubber boots

d. Fire fighting suit

e. Breathing apparatus

f. Fire fighting helmet

g. Goggles / Face shields

h. Fire fighting gloves

i. Fire fighting boots

Mitigation Equipment

a. Hazmat absorbents

b. Over-pack drums / Leak sealing devices

c. Fire extinguishers (appropriate class)

d. Hose reel

e. FF nozzles & hoses (1 nozzle, 2x20m hoses)

First Aid and rescue equipment

a. First aid kit

b. Foldable stretcher

c. Blanket

d. AED

Communication Equipment

a. Loud Hailer

b. Walkie Talkie


For Tier 1 HRI Premises only:

 Public and industrial premises with FSM, and classified as High Risk Installation by SCDF


Personal Protective Equipment (PPE)

a. Fire retardant coveralls

a. Breathing apparatus

b. Safety helmets

c. Goggles / Face shields

d. Safety gloves

e. Safety boots

Mitigation Equipment

a. Fire extinguishers (appropriate class)

b. Hose reel

First Aid and rescue equipment

a. First aid kit

b. Foldable stretcher

c. Blanket

d. AED

Communication Equipment

a. Loud Hailer

b. Walkie Talkie


No. S 772
FIRE SAFETY ACT
(CHAPTER 109A)
FIRE SAFETY
(COMPANY EMERGENCY RESPONSE TEAM)
(AMENDMENT) REGULATIONS 2020
In exercise of the powers conferred by section 61 of the Fire Safety Act, the Minister for Home Affairs makes the following Regulations:
Citation and commencement
1.  These Regulations are the Fire Safety (Company Emergency Response Team) (Amendment) Regulations 2020 and come into operation on 14 September 2020.
Amendment of regulation 2
2.  Regulation 2 of the Fire Safety (Company Emergency Response Team) Regulations 2013 (G.N. No. S 540/2013) (called in these Regulations the principal Regulations) is amended by deleting the definition of “specified premises” and substituting the following definition:
“ “specified premises” means any premises specified in Part 2 of the Schedule to the Fire Safety (Premises Requiring Fire Safety Manager and Company Emergency Response Team) Notification 2020 (G.N. No. S 768/2020).”.
Amendment of regulation 3
3.  Regulation 3 of the principal Regulations is amended —
(a)by deleting sub-paragraphs (a) and (b) of paragraph (1) and substituting the following sub-paragraphs:
(a)establish a CERT for the premises comprising 6 members, or such other number as notified by the Commissioner under section 22(4)(a) of the Act, within 6 months after the date the premises become specified premises;
(b)provide the CERT with the equipment specified in the Schedule;”; and
(b)by deleting paragraph (2).
New Schedule
4.  The principal Regulations are amended by inserting, immediately after regulation 5, the following Schedule:
THE SCHEDULE
Regulation 3(1)(b)
EQUIPMENT REQUIRED FOR CERT
1.  The following equipment must be provided to a CERT of any specified premises:
(a)5 sets of fire retardant coveralls;
(b)5 safety helmets;
(c)5 pairs of goggles or 5 face shields;
(d)5 pairs of safety gloves;
(e)5 pairs of safety boots;
(f)the requisite number and class of fire extinguishers in accordance with Singapore Standard 578:2012 — Code of Practice for Use and Maintenance of Portable Fire Extinguishers;
(g)a first‑aid kit;
(h)a foldable stretcher;
(i)a fire blanket;
(j)an automated external defibrillator;
(k)a loud hailer;
(l)4 walkie-talkies.”.
Transitional provision
5.—(1)  For the purposes of regulation 3(1)(a) of the principal Regulations as in force on 14 September 2020, despite the Fire Safety (Premises Requiring Fire Safety Manager and Company Emergency Response Team) Notification 2020 (G.N. No. S 768/2020) as in force on 14 September 2020, the date that any premises specified in paragraph (2) become specified premises is taken to be 13 March 2021.
(2)  The premises to which paragraph (1) applies are any specified premises —
(a)in respect of which a certificate of statutory completion or temporary occupation permit is issued before 14 September 2020; and
(b)that are not designated under the cancelled Fire Safety (Premises Requiring Fire Safety Manager and Company Emergency Response Team) Notification 2013 (G.N. No. S 537/2013) as in force immediately before 14 September 2020.
(3)  In this regulation, “certificate of statutory completion” and “temporary occupation permit” have the meanings given by section 2(1) of the Building Control Act (Cap. 29).
Made on 24 August 2020.
PANG KIN KEONG
Permanent Secretary,
Ministry of Home Affairs,
Singapore.
[MHA 112/2/030; AG/LEGIS/SL/109A/2015/6 Vol. 1]


 



Fire Extinguisher Brackets

Fire Extinguisher Brackets

Fire Extinguisher Brackets (Part of National CERT Equipment Supply)Extinguisher Heavy Duty Mari..

Fire Extinguishers

Fire Extinguishers

Fire Extinguishers (Part of National CERT Equipment Supply) ABS 2 / 5 KG CO2 Fire Extinguish..

JOCKEL Fire Extinguisher - ABC Dry Powder

JOCKEL Fire Extinguisher - ABC Dry Powder

JOCKEL Fire Extinguisher - ABC Dry Powder (Part of National CERT Equipment Supply) Allrounder ..

JOCKEL Fire Extinguisher - CO2

JOCKEL Fire Extinguisher - CO2

JOCKEL Fire Extinguisher - CO2 (Part of National CERT Equipment Supply) Traceless extinguishin..

JOCKEL Fire Extinguisher - Containers

JOCKEL Fire Extinguisher - Containers

JOCKEL Fire Extinguisher - Containers (Part of National CERT Equipment Supply) High-performanc..

JOCKEL Fire Extinguisher - Foam

JOCKEL Fire Extinguisher - Foam

JOCKEL Fire Extinguisher - Foam (Part of National CERT Equipment Supply) ​Bio-agents for liqui..

JOCKEL Fire Extinguisher - Kitchen / Wet Chemical

JOCKEL Fire Extinguisher - Kitchen / Wet Chemical

JOCKEL Fire Extinguisher - Kitchen / Wet Chemical (Part of National CERT Equipment Supply) Spe..

JOCKEL Fire Extinguisher - Sprinklers

JOCKEL Fire Extinguisher - Sprinklers

JOCKEL Fire Extinguisher - Sprinklers (Part of National CERT Equipment Supply) For unguarded a..

JOCKEL Fire Extinguisher - Trolley

JOCKEL Fire Extinguisher - Trolley

JOCKEL Fire Extinguisher - Trolley (Part of National CERT Equipment Supply)     ..

JOCKEL Fire Extinguisher - Water

JOCKEL Fire Extinguisher - Water

JOCKEL Fire Extinguisher - Water (Part of National CERT Equipment Supply) Proven over many yea..

Trolley Fire Extinguisher

Trolley Fire Extinguisher

Trolley Fire Extinguisher (Part of National CERT Equipment Supply)ABS 10 / 20 / 30 / 50KG CO2 T..