HONEYWELL BW, MULTI-GAS DETECTOR, GasAlertMicroClip XL
- Product Code: GasAlertMicroClip XL
- Product SKU:
- Item Code: GDTR-HA1-MGAM1-Y
- Availability: In Stock
GasAlertMicroClip XL Multi Gas Detector
HONEYWELL BW GASALERT MICROCLIP XL, 4-GAS |
DETECTOR, YELLOW CASING |
LOW/HIGH ALARM
SETTINGS BY FACTORY: -LEL 10%/20% -O2 19.5%/23.5% -CO 35PPN/200PPM -H2S
10PPM/15PPM COME WITH: -RECHARGEABLE BATTERY -WALL OUTLET CHARGING ADAPTOR -CALIBRATION TEST CAP AND HOSE -USER MANUAL GDTR-HA1-MGAM1-Y (MCXL-XWHM-Y-OR) |
Multi-gas made easier
The easy to wear, slim and compact GasAlertMicroClip provides affordable protection from atmospheric gas hazards. For standard operation with features you can count on, opt for the GasAlertMicroClip XT. For extended battery life, especially in cold weather, choose the GasAlertMicroClip XL. Both offer visual compliance at a glance with the fl ashing, green IntelliFlash™. Easy onebutton operation reduces training time and lets workers focus on the job at hand. For simple, cost-effective management of your records, calibration and bump testing, choose BW's MicroDock II automatic test and calibration system and Fleet Manager II software.
- Easy and comfortable to wear; thin and lightweight
- Easy operation and straightforward training with one-button simplicity
- Easy visual compliance with fl ashing, green IntelliFlash™
- Easy and cost effective to own
Additional GasAlertMicroClip features:
- Choose the GasAlertMicroClip XL for cold weather performance
- IntelliFlash™ verifi es operation and compliance to both the user and supervisor
- Tamper-proof, one button operation
- Powered by a rechargeable lithium polymer battery
Standard features of BW multi-gas products:
- Continuous LCD shows real-time gas concentrations
- Compact and lightweight design makes it comfortable to wear
- Water-resistant
- Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
- Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
- Bright wide-angled visual alarm bars
- Built-in concussion-proof boot
- Multi-language support in English, French, German, Spanish and Portuguese
- Conveniently manage your fl eet using Fleet Manager II
- GasAlertMicroClip XL Specifications:
Size | 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.1 cm |
Weight | 6.7 oz. / 190 g |
Temperature | -4 to +122°F / -20 to +50°C |
Humidity | 0% - 95% RH (non-condensing) |
Alarms | - Visual, vibrating, audible (95dB) - Low, High, STEL, TWA, OL (over limit) |
Tests | Audible/visual alarms on activation, sensors, battery and circuitry (continuous) |
Typical battery life | 18 hours; Recharges in less than 6 hours |
Cold weather battery life | After 2 years: 12 hours at 4°F / -20°C |
User options | Confidence beep Set STEL interval Sensor on/off Latching alarms Safe display mode Stealth mode Calibration lock Auto zero on start up O2 auto calibration on start up Set bump test interval Force bump test when overdue IntelliFlash™ interval Combustible gas measurement (%LEL or % by volume methane) User-settable calibration gas level Force calibration when overdue Low alarm acknowledge Language choices Set custom start up message |
Ratings | EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66 |
Warranty | Full two-year warranty including sensors and battery |
- Sensor Specifications:
Gas | Measuring Range | Resolution |
H2S | 0-100 ppm | 1 ppm |
CO | 0-500 ppm | 1 ppm |
O2 | 0-30.0% | 0.1% |
Combustible gases | 0-100% LEL 0-5.0% v/v | 1% 0.1% |
Honeywell BW Gas alert Microslip XL, 4-Gas detector,
yellow casing
BW, MULTI-GAS DETECTOR, GasAlertMicroClip XL/X3
The industrial Honeywell BW™ MicroClip Series is the world’s most popular multi-gas portable detector, delivering long runtime and reliability — plus small size, low cost and the easiest user experience.
Overview:
Small size. Easy to use. Reliable operation. Affordable protection. With that combination of benefits, it’s no wonder the Honeywell BW™ MicroClip Series is the world’s most popular multi-gas detector. The latest addition to the Honeywell BW™ MicroClip Series is the Honeywell BW™ MicroClip X3. This model offers a three-year warranty and an all-new O2 sensor — along with all the other benefits of workers’ favorite four-gas detector — to deliver the best combination of reliability, cost of ownership and ease of use.
OTHERS
- Alarm Type
- Audible- Visual- Vibrating
- Audible, Visual, Vibrating
- Sensor Range
- H2S (0-100ppm)- CO (0-500ppm)- O2 (0-30%vol)- LEL (0-100%LEL)
- H2S (0-100ppm), CO (0-500ppm), O2 (0-30%vol), LEL (0-100%LEL)
- Minimum Temperature
- -20 degree Celsius
- -4 degree Fahrenheit
- Humidity Range
- 0%-95%
- Benefits
- • Guaranteed runtime for
- Sub-Category
- Multi-Gas
- Maximum Temperature
- 50 degree Celsius
- 122 degree Fahrenheit
- Weight
- 190 gram
- 6.7 ounce av [Invisible]
- Standards
- CSA: Class I- Div. 1- Gr. A- B- C- D
- CSA: Class I, Div. 1, Gr. A, B, C, D
- Sampling Pump Range
- N/A
- Brand
- BW
- Wireless Technology
- BLE
- Gas Type
- H2S- CO- O2- LEL
- H2S, CO, O2, LEL
- Datalogging
- 16 hours at 15-second intervals
- Battery Run Time
- 12-18 hours
- 12-18
- Warranty
- Full two‑year (Honeywell BW™ MicroClip XL) or three‑year (Honeywell BW™ MicroClip X3) warranty
- Ingress Protection
- IP68
- User Options
- • Confidence beep
- Instrument Size
- 11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in
Features & Benefits:
- NEW! Honeywell BW™ MicroClip X3 for extended reliability with 3-year warranty
- Honeywell BW™ MicroClip XL for standard operation with 2-year warranty
- Simultaneously monitor for up to four gases including O2, H2S, CO and combustibles
- Battery runtime of 18 hours in normal temperatures: cold weather guarantee of at least 12 hour runtime for full warranty period.
- Guaranteed to run an entire shift — even at -4°F (-20°C)
- NEW! IP68 rating — unmatched water protection Compact, lightweight and easy to use — with one-button operation and no extensive training Device management with Honeywell Safety Suite.
- Flashing green IntelliFlash™ light for compliance at a glance
- Reflex™ Technology ensures sensor responsiveness for safety, uptime and worker confidence
REFERENCE: WSH Bulletin: 17 July 2014, Ref: 1314132
Confined Space Ventilation and Gas Testing
• Always carry out purging (to rid the atmosphere of hazardous contaminants) and ventilation (to render the environment safe for work) prior to confined space entry. For improved ventilation effectiveness, a push-pull system involving both forced ventilation and exhaust ventilation is recommended wherever practicable. A powerful blower and a long ventilation duct (capable of reaching the bottom of the confined space) are necessary to prevent short-circuiting and ensure that the ventilation is adequate.
• Carry out gas testing prior to initial entry to verify that the atmosphere of the confined space is safe for entry. It is important that gas testing be carried out at different locations and elevations of the confined space. As stipulated in the WSH (Confined Spaces) Regulations, it is mandatory for gas testing to be carried out by a Confined Space Safety Assessor.
• Initial gas testing is followed by continuous gas monitoring and re-testing at regular intervals to verify that the work environment remains safe for continued work. Continuous monitoring is achieved by equipping confined space workers with a portable gas detector capable of providing an audiovisual alert once hazardous atmospheric conditions are detected. Mechanical ventilation should be provided continuously so that a safe work environment can be maintained as the work proceeds. Should the confined space be left vacant and without continuous gas monitoring for more than 30 mins, carry out gas testing once again before re-entry.
WSH, 27 November 2020:
Employers, principals and contractors performing similar work are advised to put in place the necessary controls to p