MULLION FIREMAN JACKET & TROUSERS, 531(1MI9) SIZE: L

  • Product Code: 1MMF & 1MPF
  • Product SKU:
  • Item Code: CLFF-MUL-FB...-L
  • Availability: In Stock

MULLION FIREMAN JACKET & TROUSERS, 531(1MI9) SIZE: L 

 

MULLION FIREMAN SUIT, COMPLETE

C/W: JACKET, TROUSERS, ORANGE (EN469),


EN469(2020) FIRE FIGHTER'S PROTECTIVE 2
CLOTHING certified

PAB FIRE COMPACT FIREMAN HELMET, YELLOW/WHITE, GLOVES 2MZO RESCUE2 (EN659), BOOTS, ETCHE, FIREMAN SABF BOOTS (EN 15090:2012, EN ISO 20345 S5) & CARRYING BAG EC-MED APPROVED TO SOLAS, EN 469 2020  





(Part of fireman's outfit solas requirements)

FIRE FIGHTING SUIT, MULLION, FIRE FIGHTER

INTERVENTION JACKET & TROUSERS WITH SUSPENDERS,

531(1MMF & 1MPF), COLOUR: ORANGE, TWO‐LAYER

ARAMID (NOMEX) THERMAL INSULATION BARRIER, C/W:

CARRYING BAG

DOUBLE CERTIFICATION: EN469 AND SOLAS

MADE IN BELGIUM

Features:

  • Professional fire fighter jacket and trousers that complies to SOLAS/MED regulations

Specifications:

Fire-Fighting Jacket

  • Fire resistant garment with two-layer aramid thermal insulation barrier. Breathable. Excellent wicking performance. Outer shell treated with water repellent finish.
  • Sleeve narrowing by touch and close fastening
  • Stand-up collar with touch and close fastening to protect the neck
  • Front zip closure under flap
  • Flame resistant triple trim reflective tape on chest, back and arms for optimum visibility day and night

Fire-Fighting Trousers

  • Fire resistant garment with two-layer aramid thermal insulation barrier. Breathable. Excellent wicking performance. Outer shell treated with water repellent finish.
  • Front fly with zipper
  • Adjustable elasticated shoulder braces
  • Flame resistant triple trim reflective tape on legs for optimum visibility day and night

Applications:

  • Offshore Facilities
  • Supply / Commercial Vessels
  • Bulk Carriers
  • Oil And LPG Tankers
  • Container And Load Vessels That Operate In Cold Water

Certifications / Safety Approvals:

  • SOLAS
  • EN 469 : 2020
Mullion is a brand and division of Sioen Apparel, which is part of the Sioen Industries Group.
  • Role: Mullion specializes in high-quality professional protective maritime clothing, including personal floatation devices (PFDs), lifejackets, and immersion suits.
  • Context: It is a key brand within Sioen’s marine safety portfolio, often working alongside sister brand Ursuit to provide safety gear for extreme working environments like offshore oil rigs and fishing industries.
  • Company Structure: Sioen Apparel is one of three divisions of Sioen Industries (along with Sioen Coating and Sioen Chemicals).

Protective clothing for firefighters - Performance requirements for protective clothing for firefighting activities

This document specifies minimum performance requirements for protective clothing designed to be worn during firefighting activities. The requirements detailed in this document cover design, heat and flame, mechanical, chemical, comfort, and visibility.
This document covers the general clothing design, the minimum performance levels of the material used, the methods of test to be used to determine these performance levels, marking and information supplied by the manufacturer.
This document makes distinction between firefighting activities dividing them into two performance levels based on a risk assessment:
-   Level 1: specifies the minimum requirements for firefighting clothing involving work associated with outdoor firefighting and their support activities, taking into account the environments and conditions of the expected operational scenarios of such firefighting activities.
The level 1 is not applicable for protection against risks encountered in fighting fires or rescue from fire activities in structures, unless combined to a level 2 or other specialized PPE.
-   Level 2: specifies the minimum requirements for firefighting clothing for risks encountered in fighting fires and rescue from fire in structures.
The distinction between Level 1 and Level 2 clothing is restricted to the requirements for heat and flame (X1 or X2 - Heat and Flame). These levels of protection can be reached by a single garment or a combination of separate garments.
Additional marking provides two grades of protection for Y (protection against water penetration) and Z (water vapour resistance). It is essential that these performance grades are indicated on the marking of the clothing and explained in the instructions for use.
This document does not cover protective clothing for wildland firefighting, specialized firefighting in a high amount of radiant heat where reflective clothing is required and/or advanced technical rescue operations dealing with hazardous chemicals, working with chainsaws and water and rope rescue.
This document does not cover protection for the head, hands and feet or specific protection against other hazards e.g. chemical, biological, radiological and electrical hazards. These aspects may be covered in other European Standards.


  • EN ISO 13688 : 2013


A fireman's outfit marked with Xf2Xr2Y2, and Z2 refers to Level 2 protective suit under the EN 469 standard. This classification indicates the highest level of protection, specifically required for structural firefighting and high-risk enclosed spaces like ships.
The specific markings stand for:
  • Xf2 / Xr2: Resistance to convective heat (Xf) and radiant heat (Xr) at the highest performance level (Level 2).
  • Y2: Resistance to water penetration, which includes a mandatory moisture barrier for protection against steam and chemicals.
  • Z2: Water vapor resistance (breathability), ensuring the garment can effectively manage heat stress for the wearer.
As of 2026, European maritime regulations require that shipboard firefighting suits be upgraded to this Level 2 standard for enhanced safety in hazardous environments.
Structural Firefighting Gear (EN 469 Level 2)


From ABS (Industry Reminder on Firefighting Suits),

EN 469:2020 The European standard for firefighter protective clothing, EN 469, underwent revisions in 2020.

Based on the updated standard EN 469:2020, there are three criteria classified as level 1 or level 2: 

• Thermal Performance (X1 or X2) 

• Water Penetration Resistance (Y2 or Y2) 

• Breathability/Water Vapor Resistance (Z1 or Z2)   

Specifically, the difference in Water Penetration Resistance is that level 2 (Y2) fire suits include a moisture barrier, while level 1 (Y1) fire suits do not. It's important to note that both types of fire suits, with or without a moisture barrier, are approved according to EN 469:2020.  In the updated standard, performance levels are exclusively determined by a garment’s thermal performance, with X now representing both radiant heat and flame contact heat. Level 1 meets lower requirements suitable only for outdoor firefighting, while Level 2 meets higher standards necessary for structural firefighting operations, including indoor and enclosed spaces. Notably, the garment's pictogram still includes grades for resistance to water penetration and water vapor to provide an indication of performance. 


What is fire suit EN 469 2020?

This document specifies minimum performance requirements for protective clothing designed to be worn during firefighting activities. The requirements detailed in this document cover design, heat and flame, mechanical, chemical, comfort, and visibility.